KOCH ACOUSTICAL ENCLOSURES

KOCH acoustical enclosures control industrial noise, improve worker productivity and reduce workplace fatigue. They are engineered for long service life, offer maximum user flexibility, have a handsome appearance and meet OSHA requirements.  KOCH enclosures are the most advanced and effective enclosures available.

KOCH enclosures and barriers are engineered for a lifetime of stand-alone strength!  Load-bearing panels accommodate vertical and horizontal loading; no angle irons or separate framework needed.

KOCH acoustical enclosures and barriers have:
1.   Roll-formed, tongue-in-groove panels
2.   Removable panels
3.   Acoustical  double-glazed windows
4.   Single and double leaf doors
5.   Acoustical doors
6.   Formed corners and flash corners
7.   Ventilation sound trap
8.   Conveyor sound trap
9.   Ventilation panel
10. Electrical connections
11. Exterior finish
12. Roof support steel

KOCH acoustical enclosures
KOCH Acoustical Enclosures


Acoustic Characteristics of
KOCH enclosures and barriers

Transmission Losses in dB

T
H
I
C
K
N
E
S
S

Preferred Octave Bands (Hz) 63 125 250 500 1000 2000 4000
2" 5 13 23 32 43 52 53
3" 8 16 26 35 46 55 56
4" 22 23 32 40 50 57 63
6" 25 28 47 55 58 59 66

Sound Absorption Coefficients

T
H
I
C
K
N
E
S
S

Preferred Octave Bands (Hz) 125 250 500 1000 2000 4000 NRC
2" .40 .80 .99 .99 .99 .99 .95
3" .55 .99 .99 .99 .99 .99 .95
4" .76 .99 .99 .99 .90 .89 .95
6" .99 .99 .99 .99 .99 .99 .95


Online Request for Quote